High-Low Pressure Test System

Safe pneumatic operation –no heat, flame or spark risk and Problem-free stop/start applications. Fully enclosed easy access controls and bulkhead. and hose storage

For more information
Call 713-481-2543

LOW SIDE
With a nominal pressure ratio of 10:1, the air-driven liquid pump utilizes a single air head to boost liquid pressures to a maximum of 1600 PSIG.

Typical Performance Characteristics (@100 PSIG air supply pressure)

1000 in3/min @ 400 psig

500 in3/min @ 990 psig
Technical Data:

Power: 1.5 HP

Air Head: single

Max Air Pressure: 150 PSIG

Max cycles: 80/min.

Nominal ratio (“dash number”): 10:1

Actual area ratio: 11.5:1

Max outlet pressure (continuous): 1600 PSIG

Max outlet pressure (intermittent): 1600 PSIG

Displacement / cycle: 4.05 cu. in.

Max flow: 1215 cu. in./min.

HIGH SIDE

With a nominal ratio of 302:1, the air-driven liquid pump utilizes a double air head to boost liquid pressures to a maximum of 30,000 PSIG.
Typical Performance Characteristics (@100 PSIG air supply pressure):

91.5 in3/min @ 7000 psig

20.1 in3/min @ 20,000 psig
Technical Data:

Power: 2HP

Air Head: double

Max Air Pressure: 150 PSIG

Max cycles: 80/min.

Nominal ratio (“dash number”): 302:1

Actual area ratio: 346:1

Max outlet pressure (continuous): 30,000 PSIG

Max outlet pressure (intermittent): 50,000 PSIG

Displacement / cycle: 0.27 cu. in.

Max flow: 61 cu. in./min.